Download 
text/csvAlveoVecchio database(CSV | 1 MB)

Database [.csv]: il file è diviso in colonne, ciascuna colonna rappresenta un gruppo specifico di informazione. In Tabella 3 sono riportate le specifiche di ciascuna colonna. 

Column Description Type Interval
BEAM Beam number String 1,2,3,4
CABLE Cable number Integer 1 to 14
SECTION Segment number Integer 1 to 335
POSITION Location along the cable Float 0 to ±16.65
RIMT.C Reflectometric result (corrosion) String ‘0-1’,‘1-2’,‘2-3’,‘3-4’,‘4-5’
RIMT.V Reflectometric result (void) String ‘0-1’,‘1-2’,‘2-3’,‘3-4’,‘4-5’
RIMT.C (Raw) Reflectometric result (corrosion) Float 0 to 5
RIMT.V (Raw) Reflectometric result (void) Float 0 to 5
DR.V Radiography result (void) Integer 0,1,2
DR.B Radiography result (corrosion) Integer 0,1,2
GPR Radar result (corrosion) Integer 0,1,2
TOM Tomography result (void) Integer 0,1,2
D.C. Corrosion of duct String ‘0/16’ to ‘16/16’
D.A. Absence of integrity of the duct String ‘0/16’ to ‘16/16’
D.P Perforation of duct String ‘0/16’ to ‘16/16’
G.F Grout fracturing Integer 1,2,3,4,5
G.V Grout voiding String  ‘=0%’,’<25%’,‘<50%’,‘<75%’,’<100%’ ‘=100%’
W.C Corrosion of wires Float ‘0/12’ to ‘12/12’
W.R Area reduction of wires String  ‘=0%’,‘<2%’,’<5%’,’<10%’,’<20%’,‘>20%’
W.R (Raw) Area reduction of wires Float 0 to 1 (percentage)
W.I Interruptions of wires Float ‘0/12’ to ‘12/12’

Tabella. Specifiche di ciascuna colonna del file