Download
Database [.csv]: il file è diviso in colonne, ciascuna colonna rappresenta un gruppo specifico di informazione. In Tabella 3 sono riportate le specifiche di ciascuna colonna.
Column | Description | Type | Interval |
---|---|---|---|
BEAM | Beam number | String | 1,2,3,4 |
CABLE | Cable number | Integer | 1 to 14 |
SECTION | Segment number | Integer | 1 to 335 |
POSITION | Location along the cable | Float | 0 to ±16.65 |
RIMT.C | Reflectometric result (corrosion) | String | ‘0-1’,‘1-2’,‘2-3’,‘3-4’,‘4-5’ |
RIMT.V | Reflectometric result (void) | String | ‘0-1’,‘1-2’,‘2-3’,‘3-4’,‘4-5’ |
RIMT.C (Raw) | Reflectometric result (corrosion) | Float | 0 to 5 |
RIMT.V (Raw) | Reflectometric result (void) | Float | 0 to 5 |
DR.V | Radiography result (void) | Integer | 0,1,2 |
DR.B | Radiography result (corrosion) | Integer | 0,1,2 |
GPR | Radar result (corrosion) | Integer | 0,1,2 |
TOM | Tomography result (void) | Integer | 0,1,2 |
D.C. | Corrosion of duct | String | ‘0/16’ to ‘16/16’ |
D.A. | Absence of integrity of the duct | String | ‘0/16’ to ‘16/16’ |
D.P | Perforation of duct | String | ‘0/16’ to ‘16/16’ |
G.F | Grout fracturing | Integer | 1,2,3,4,5 |
G.V | Grout voiding | String | ‘=0%’,’<25%’,‘<50%’,‘<75%’,’<100%’ ‘=100%’ |
W.C | Corrosion of wires | Float | ‘0/12’ to ‘12/12’ |
W.R | Area reduction of wires | String | ‘=0%’,‘<2%’,’<5%’,’<10%’,’<20%’,‘>20%’ |
W.R (Raw) | Area reduction of wires | Float | 0 to 1 (percentage) |
W.I | Interruptions of wires | Float | ‘0/12’ to ‘12/12’ |
Tabella. Specifiche di ciascuna colonna del file